Rechargeable 1200wh Battery Solar Portable Power Station
Cycle Life ≥1000 Times
Short Circuit Protection
Nominal Voltage 3.2V
rry.
Battery
Cell
|
Item
|
Rating
|
Remark
|
Battery Cell
|
32140
|
150000mAh 21pcs Li-ion 32140 batteries
|
|
Rated Capacity
|
1008Wh
|
2C Discharge
|
|
Nominal Voltage
|
3.2V
|
Average discharge voltage.
|
|
Cut Down Voltage
|
2.0V
|
3.6v discharge to 2.0v
|
|
Maximum charge voltage
|
3.6V±0.05V
|
||
Charging method
|
CC/CV
|
Charge with constant current 0.2C to 4.2V,
then charge with constant voltage 4.2V till charge current is less than 0.01C |
|
Initial internal resistance(mΩ)
|
≤ 3mΩ
|
/
|
|
Operating Temp for
charging
|
-0℃~45℃
|
Charge by 0.2c current.
|
|
Operating Temp for
discharging |
-10℃~45℃
|
Discharge at 0.2C current.
|
|
Cycle life
|
≥1000 Times
|
Charging: 0.2C Constant Current and constant voltage charged to 3.6V, current less than or equal to 0.02C will be cut off.
Discharging: 0.2C discharge to 2.0V will be cut-off.
When the discharge capacity drops to 80% of the standard capacity, the test is stopped.
|
|
Charging |
Charging method
|
CV/DC
|
Mode of Input Voltage
|
Input Voltage
|
DC:5V~28V
|
Rated Input Voltage
|
|
Input current
|
DC:6A Max
Type-c:2.4A 3A 3A 3A 5A Solar :6A Max |
Rated Input Current
|
|
Quiescent current
|
≤400uA
|
Standby Current less than 400uA
|
|
Input Protection Voltage
|
29V
|
|
|
Output
performance
|
Output voltage
|
Type-c 1/Type-c 2:PD 100W
5V/9V/12V/15V/20V
USB1/USB2:QC3.0 18W
5V/9V/12V
USB3/USB4:10W 5V
DC1/DC2/DC3/Car Cigarette*2
Lighter:12V~13V
|
|
Output current
|
Type-c 1/Type-c 2:PD 100W
2.4A 3A 3A 3A 5A
USB1/USB2: 3A/2A/1.5A
USB3/USB4: 2.1A
DC1/DC2/DC3/Car Cigarette
Lighter:10A
|
||
AC output
|
220V 50Hz/110V 60Hz
|
||
Over Discharging
Protection Voltage
|
3.0±0.25V
|
When the voltage is below 3.0v, the output
voltage is disconnected by the system.
|
|
Over current
protection current
|
100A
|
When the output current is too large, the
output voltage will be disconnected.
|
|
Short Circuit Protection
|
√
|
When the positive and negative terminals of the output short-circuit, the output voltage will be disconnected by the system
|
Suggestions for using
the Products
Application
1200wh
Household Electricity Demand
Back-up power supply in hotels,
banks and other places
Small Industrial Power Demand
Peak shaving and valley filling,
photovoltaic power generation